Euchner AS-i 3.0 Command Interface Manual do Utilizador Página 72

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 98
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 71
AS-i 3.0 Command Interface Commands of the Command Interface
Subject to reasonable modifications due to technical advances Id.-No.: 102875 Issue date - 3.12.2007 EUCHNER GmbH + Co. KG
Kohlhammerstraße 16, D-70771 Leinfelden-Echterdingen Tel. +49/711/7597-0, Fax +49/711/753316
72
4.7.7 Language-select
(Function 0E
16
)
Use this function to set the display language.
Set:
Read:
Request
Byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
17D
16
2T circuit
30E
16
4
language
1
1. Value: 0= default (no changes), 1= english, 2= german, 3= french, 4= italian, 5= spain.
Response
Byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
17D
16
2T result
Request
Byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
17E
16
2T circuit
30E
16
Response
Byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
17E
16
2T result
3
language
1
1. Value: 0= default (no changes), 1= english, 2= german, 3= french, 4= italian, 5= spanish.
Vista de página 71
1 2 ... 67 68 69 70 71 72 73 74 75 76 77 ... 97 98

Comentários a estes Manuais

Sem comentários