AS-i 3.0 Command Interface Commands of the Command Interface
Subject to reasonable modifications due to technical advances Id.-No.: 102875 Issue date - 3.12.2007 EUCHNER GmbH + Co. KG
Kohlhammerstraße 16, D-70771 Leinfelden-Echterdingen Tel. +49/711/7597-0, Fax +49/711/753316
27
4.3.3.11 Commands 10 - 13: Safety unit diagnosis and shutdown-history
In the case of a second generation safety monitor, the shutdown-history can be
read additionally to the safety unit diagnosis.
If an OSSD abandons the state green, the states of all devices are hold on at this
moment. Therefore it is possible to detect the cause for the turning-off läter.
If there has been no turning-off of the related OSSD since the start, all devices are
grey.
If the ACYC_TRANS slave address is "0", the internal monitor is activated, other-
wise the external one.
!!!
The commands 10 ... 15 are available only with safety monitors (external and
integrated) in the version 2 and higher.
Command Description
10 safety monitor diagnosis
11 shutdown-history, separate for each release circuit
12 safety monitor diagnosis, but the module allocation has been
considered
13 shutdown-history, but the module allocation has been considered
Request buffer (only for commands 10 + 11)
Byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
1 OSSD: 0=OSSD 1; 1=OSSD 2
Response buffer
Byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
0 reserved 00
16
1
monitor state
1
2
OSSD 1 state
2
3 OSSD 2 state
4
number of not green
3
devices
5—
6 device index 32
7
device
4
colour 32
8 device index 33
9 device colour 33
...
132 device index 95