4.2.4 RD_74_75_ID
With this function the ID string of a slave according to profile S-7.4 or the 16-bit
slave configuration according to profile 7.5 is being read. Since the string can be
longer than the command interface, it is written into the buffer. The content of the
buffer can read in parts from index i.
The first byte of the buffer is the length of the read string.
If i 0, the string is being read from the slave, otherwise the function responses
out of the memory, the data can be read consistently.
By a 7.5 slave is the request always 1. The response byte contains the cyclic 16-
bit slave configuration according to S-7.5 profile (analog/transparent bits are can-
celled). If the response is 08
16
, that means that the cyclic 16-bit configuration could
not be detected.
Response
byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
15B
16
2T result
3 buffer byte i
……
n+2 buffer byte i+n-1
Request
byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
15C
16
2T circuit
3 slave address
4i
Response
byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
15C
16
2T result
3 buffer byte i
……
n+2 buffer byte i+n-1