Manual EKS ActiveX
®
Module Ethernet TCP/IP
3.5 Properties
3.5.1 Port
Description Selects the port for the TCP connection
Syntax object.Port = String Value;
Comments Possible values are:
2444
2445
This property is applied by calling the method Open. The value must match the setting
on the EKS.
Data type String
Default value 2444
3.5.2 IPAddress
Description Selects the IP address for the TCP connection
Syntax object.IPAddress = String Value;
Comments Possible values are:
192.168.1.1
This property is applied by calling the method Open. The value must match the setting
on the EKS.
Data type String
Default value 192.168.1.1
3.5.3 KeyType
Description Defines the type of Electronic-Key used (read-only Electronic-Key* or read/write
Electronic-Key)
*Earlier transponder type. We do not recommend using this transponder type in new installations.
Syntax object.KeyType = KeyTypeConstants Value;
Comments Possible values are:
EKS_KEY_READWRITE = 1
EKS_KEY_READONLY = 8
This property is applied by calling the method Open.
Data type KeyTypeConstants (Enumeration)
Default value EKS_KEY_READWRITE
Page 10/20 Subject to technical modifications 102030-02-10/12