Operating Instructions Safety Switch CES-AP-C.2-CH
16
System status table
Operating mode
Actuator/
door position
Safety outputs
OA and OB
LED indicator
output
State
STATE (green)
DIA (red)
Normal operation
closed on
Normal operation, door closed
closed on
flashes 
quickly
2 Hz
Normal operation, door closed, actuator in the boundary area ¨ Re-adjust door
open off
1 x Normal operation, door open
Fault display
closed off
3 x Defective actuator (e.g. fault in code or code not readable)
X off
4 x
Output error  
(e.g. short circuits, loss of switching ability)
X off
5 x Internal fault (e.g. component faulty, data error)
Key to symbols
LED not illuminated
LED illuminated
10 Hz (8 s)
LED flashes for 8 seconds at 10 Hz
3 x
LED flashes three times, and this is then repeated
X Any state
After  the  cause  has  been  remedied, faults  can  generally  be  reset  by  opening 
and closing the door. If the fault is still displayed afterward, briefly interrupt the 
power supply. Please contact the manufacturer if the fault could not be reset after 
restarting.
Important:
If you do not find the displayed device status in the System status table, this indi-
cates an internal device fault. In this case, you should contact the manufacturer.