Technical Data
Parameter Value Unit
min. typ. max.
Housing material Fortron, reinforced thermoplastic, fully encapsulated
Dimensions 50 x 50 x 20.2 mm
Weight 0.08 kg
Ambient temperature -25 - +70 °C
Degree of protection IP67
Installation position Any
Method of operation Inductive
Power supply Via evaluation unit
In combination with actuator CES-A-BBA or CES-A-BCA
Assured switch-off distance S
ar
--47
mm
Operating distance for center offset m = 0
1)
- Switch-on distance - 15 -
- Assured switch-on distance S
ao
10 - -
- Switching hysteresis 2 3 -
In combination with actuator CES-A-BQA on evaluation unit CES-A-UBA-01B
Assured switch-off distance S
ar
--60
mm
Operating distance with vertical approach direction
Center offset m = 0
1)
- Switch-on distance - 23 -
- Assured switch-on distance S
ao
16 - -
- Switching hysteresis 2 3 -
Operating distance with side approach direction
Distance in x direction = 10 mm
- Switch-on distance - 28 -
- Assured switch-on distance S
ao
24 - -
- Switching hysteresis 1 1.3 -
Connection cable - - 25 m
1) These values apply for surface installation of the read head and the actuator.
Ordering table
Series Cable/connection type Comment Order no. / item
CES-A-LQA-SC
SC
M8 plug connector
2 safety screws M4 x 14 are supplied
095650
CES-A-LQA-SC
H11 H12SH1
BN
WH
1
4
3
Screen
Read head
Evaluation unit
CES-A-UBA-...