Euchner CES-A-C5H-01 (Unicode) Manual do Utilizador Página 16

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 30
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 15
System Manual Safety System CES-A-C5...
16
8
3
5
7
4
21
6
Pin assignment safety switches CES-A-C5...
LED indicators
STATE LED green Normal operation
Flashing Teach-in operation (for further signal function
see status table)
OUT/ERROR LED yellow Valid actuator detected
LED red - Internal electronics fault
- Invalid teach-in operation
(see status table)
Reset
In case of an operating fault, the evaluation unit can be reset to the operating state
by interrupting the power supply for approx. 10 seconds.
1 0 V 5 OUT
2 + UB 6 + LA
3
LA 7 -LAB
4
LB 8 +LB
View of connection side of the device
The screen on the connection cable is con-
nected internally to the device screen bond-
ing clamp via the knurled nut on the M12
plug connector.
Vista de página 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 29 30

Comentários a estes Manuais

Sem comentários